Specifications
| Parameter | Value |
| High Speed ADC-s | 2 × 20 MHz, 16 bit |
| High Precision ADC-s | 4 × 700 kHz, 18 bit |
| DAC-s | 5 × 16 bit |
| FPGA | 120 MHz, Floating Point |
| Number of curves per second | Limited only by Z scanner resonance frequency** |
| PC Interface | USB 2.0, Ethernet |
| Program SDK | LabView |
* HybriD AFM™ controller is used in combination with PX Ultra series AFM controllers.
** Tested with up to 10 kHz scanners
HybriD Mode™ (HD-AFM™ Mode) is a new AFM technique that opens new dimensions to investigate the nanoworld.
![]() |
![]() b) |
|
Shown on graphs: |
In HybriD Mode™ the tip-sample distance is modulated according to the quasi-harmonic law. Thus tip enters a force interaction with the sample thousands of times per second. Force-distance curve analysis enables maps of topographical, mechanical and electrical properties of the sample to be extracted with high spatial resolution. High-performance electronic components and unique algorithms implemented in the state-of-the-art HybriD Controller provide superb level of real-time signal processing and analysis. HybriD Mode™ provides a wealth of data within a single experiment cycle, eliminates lateral forces, and provides high stability for long-term experiments.
|
Complex Study of Polymers In comparison with common AFM techniques, HybriD Mode™ allows the response given by different material properties to be separated. This is essential in studies of composite materials, e.g. polymer blends. A 3D AFM Image of Polystyrene islands in a Polyethylene matrix is shown on the left as an example. The Elastic modulus map is overlaid with topography. PE regions (16 MPa, blue color) are seen on the top of PS islands (3 GPa, green color). |
|
| Polystyrene islands in a Polyethylene matrix. Scan size: 3×3 μm |
| Electrical Properties Characterization | |
|
|
|
| Carbon Nanotubes on Silicon. (a) Topography, (b) Current, (c) Elastic Modulus | |
Electrical characterization of objects, which are weakly attached to the surface, has always been a challenge when using standard AFM modes like Spreading Resistance. Usually tip moves or abrades the objects of interest. HybriD Mode™ eliminates the impact of lateral forces dramatically, simplifying these experiments.
Comparison of conductive and mechanical maps shown in this example allows the clear identification of single nanotubes and bundles.
| Biological Applications. Measurements in Liquid | |
|
HybridD Mode™ uniquely enables long-term experiments in liquid medium allowing the lowest force interaction and eliminating force sensor drift. Additional information about mechanical properties of the sample significantly increases the value of experimental data. Furthermore, there is no need to determine the resonance peak of cantilever when using HybridD Mode™. |
![]() |
| Stem Cell fragment in Liquid (a) Topography (b) Elastic Modulus Elastic Modulus range: 0.2-1.5 kPa |
|
| Breaking the Force Limits | |
|
|
|
|
Tin-Bismuth alloy. (a) Topography, (b) Elastic Modulus, (c) Surface Potential |
|
HybriD Mode™ uniquely enables stiff materials to be distinguished from each other by using AFM probe. Areas corresponding to Bismuth (32 GPa, light-blue color) and Tin (50 GPa, melon color) are clearly identified. The mechanical properties map corresponds well with the surface potential image.
Fully automated AFM integrated with Inverted Light Microscope for biological research
General information
LIFE is Atomic Force Microscope with XYZ scanning measuring head compatible with inverted optical microscope with NA 0.55 condensers. It is used for biological and medical researches in physiological conditions.
AFM and ILM integration
Integration of two powerful research instruments is usually a point of compromise. ILM functionality is often obstructed by AFM integration in terms of either optical methods available or limited condenser aperture.
The LIFE is not the case. The whole variety of powerful ILM methods (dark field, phase contrast, fluorescence imaging, etc.) is still available with LIFE. It is compatible with 0.55 NA ILM condens¬ers and ready for integration with Olympus IX71/IX81, Zeiss Axio Observer, Nikon Ti. Integration with other ILMs is available up on request.
6 scanning axes
PX Pro controller allows closed loop operation with up to 6 scanning axes. Basic XYZ scanning is done by the probe and provided by decoupled flexure stage. In addition, either 100 μm XY stage or 100 μm Z stage can be installed into the base of the unit. One of scanning axis is kept for the ILM objective scanner.
ectDrive cantilever excitation system
Amplitude modulation AFM modes are of great importance for investigation of soft biological speci¬mens. Because of the low Q-factor of the cantilever and complex mechanical design of cantilever/sample holders, a number of spurious resonances of the cantilever occur making it difficult to operate in AM-AFM modes in liquid.
The LIFE uses the specially developed DirectDrive cantilever excitation system that allows to avoid these problems and to get clear cantilever resonance curve. Corresponding cantilever holder is completely disassemble and washable, that allows to hold high level of cleanness during experiments.
Automation and precision
The LIFE is a fully automated AFM. Automation of laser-cantilever-photodiode optical chain alignment is very convenient for operation in liquid, where such alignment is quite tricky usually. Automated XY sample positioning table provides fast, precise and easy sample positioning. In addition, the XY sample table can be equipped with optical encoders that allows precise scanning of up to ~ mm field with AFM. The specially designed LIFE measuring head lifting mechanism makes sample/cantilever exchange much easier compare to other commercial biological AFMs.
Panoramic optical view, MultiScan and ScanStitch
The Nova PX software provides many features based on high automation level of the LIFE. Panoramic optical view allows collection of high resolution, large scale images of the sample and then operation with these data is the same as one operates with interactive maps. Multiscan and ScanStitch provide easy acquisition of scans with ~ mm scan size and overlay AFM scans with the optical image.
Fluid cell
The LIFE perfusion fluid cell provides precise sample temperature control in the range from 10 to 60 0C. It operates with standard glass bottom Petri dishes or regular microscopy cover glasses. Careful selection of materials cell made from allows keeping high pureness of the experiment. All fluid cells parts are fully washable.
![]() |
![]() |
|
DirectDrive cantilever holder and glass block |
Closed perfusion liquid cell. Temperature range 10 .. 60oC |
Applications
With its wide variety of techniques and modes of probe measurements, the Bio AFM LIFE is applicable for many challenges in life science and biotechnology.
- Molecular and cellular biology research
- Live cell research
- Microbiology and virus research
- Cell-cell and cell-substrate interactions
It can be applied in biology, medical and pharmaceutical research and the food industry.
- Tissue growth and physiology studies
- Targeted Drug delivery mechanisms
- Coatings or powders in air or liquid
Solution exchange and temperature control are optional items that can be provided. The AFM integrated with an optical microscope is a powerful multi technique platform for biological and medical scientific research.
Specifications
Measuring modes and techniques
Contact AFM, Amplitude Modulation AFM, AFM spectroscopy, AFM lithography (force, voltage), Raster Spring Imaging, LFM, FMM, PFM and Switching Spectroscopy, EFM, Kelvin Probe Force Microscopy, MFM.
ILM compatibility
- Zeiss Axio Observer: Axio Observer
- Olympus: IX product line
- Nikon: TE 200, Ti
AFM measuring head
- CL scan range: X,Y 100 × 100 μm, Z 20 μm
- Linearity: 0.03%
- OBD sensor alignment: automated
- OBD sensor laser wavelength: 850 nm
Fluid cell
- Perfusion and gas flow: available
- Temperature range: 10 .. 60°C
- Temperature control accuracy: 0.1°C
Motorized stage
- Sample positioning range: 20 × 20 mm
- Measuring head positioning range: 3 × 3 mm
- Min step: 0.3 μm
- Optical encoders: available up on request
Replaceable sample scanning stages
- XY CL scanning range: 100 × 100 μm
- Z CL scanning range: 100 μm
Objective scanner
- CL scanning range: 100 μm
NT-MDT enjoys a 20-year history in instrumentation created specifically for nanotechnology research, leading the field in originality, quality, and high tech development.
We strive for next-generation SPM technology, whether it be in pure modularity that allows a university or industrial lab to start with a cost-effective core product and build to a grand, multi-user research center or the ultimate amalgamation of SPM with related technologies that has resulted in ultramicrotomy for nanotomography and spectroscopy-based instruments that meld the world of imaging with the world of chemical analysis. We believe passionately in pushing the envelope for rapid innovation while still delivering superb customer service.
Whether you are engaged every day in nano research or just contemplating it, coupling your specific scientific knowledge and expertise with our competence in instrument creation will produce the highest quality research results currently available.
Automated AFM-Raman-SNOM system for a wide range of applications
General information
The World’s first fully automated AFM-Raman-SNOM instrument. Integration of AFM with multiple optical techniques: confocal Raman/fluorescence microscopy, SNOM, TERS etc. Comprehensive sample characterization on the nanoscale – easy and fast.