Golden Series

High Resolution NONCONTACT "GOLDEN" Silicon AFM Probes NSG01 series, resonant frequency 87-230kHz, force constant 1,45-15,1N/m.

High Resolution NONCONTACT "GOLDEN" Silicon AFM Cantilevers NSG10 series, resonant frequency 140-390kHz, force constant 3,1-37,6N/m.

High Resolution NONCONTACT "GOLDEN" Silicon Cantilevers NSG30 series, resonant frequency 240-440kHz, force constant 22-100N/m.

High Resolution NONCONTACT "GOLDEN" Silicon AFM probes NSG03 series, resonant frequency 47-150kHz, force constant 0,35-6,1N/m.

High Resolution NONCONTACT "GOLDEN" Silicon AFM Probes NSG01, (resonant frequency 87-230kHz, force constant 1,45-15,1N/m

Equipped with special alignment grooves for easy chip adjustment and laser alignment in SOLVER NANO and NANOEDUCATOR II microscopes (NT-MDT Co.)

AFM probes for Force Modulation Mode FMG01 series, resonant frequency 40-96kHz, force constant 1-5N/m.

AFM Probes for contact mode CSG11 series, each chip has two cantilevers, resonant frequency 7-14kHz, 14-28kHz; force constant 0,01-0,08N/m, 0,03-0,2N/m.

High Resolution CONTACT "GOLDEN" Silicon Cantilevers CSG10 series with special alignment grooves for easy chip adjustment and laser alignment in SOLVER NANO and NANOEDUCATOR II microscopes (NT-MDT Co.)

Subcategories

AFM probes for Noncontact/Semicontact Modes with wide range of resonant frequencies and force constants.
Can be supplied with Au or Al reflective coating, without tips, bare, with conductive or magnetic coating.

AFM probes for Force Modulation Mode. Can be supplied with Au or Al reflective coating, without tips, bare, with conductive or magnetic coating.

AFM probes for CONTACT modes. Can be supplied with Au or Al reflective coating, without tips, bare, with conductive coating.

Any noncontact probes provides by NT-MDT (NSG01, NSG10, NSG03, NSG30, FMG01 series) are available with one of the following conductive coating - TiN, PtIr and Au.
Please, choose the coating you are interested in and see the cantilever specificaitons which are available with this coating.

Noncontact cantilevers NSG01, NSG10, NSG03, NSG30, FMG01 series with PtIr conductive coating. Thickness of the coating is 20-30nm. Typical tip curvature radius is 35nm.
 

Noncontact cantilevers NSG01, NSG10, NSG03, NSG30, FMG01 series with TiN conductive coating. Thickness of the coating is 20-30nm. Typical tip curvature radius is 35nm.

Noncontact cantilevers NSG01, NSG10, NSG03, NSG30, FMG01 series with Au conductive coating. Thickness of the coating is 20-30nm. Typical tip curvature radius is 35nm.

AFM probes for Magnetic mode (MFM) with CoCr magnetic coating.

Noncontact/Semicontact and Contact AFM probes without tips.