A compact bench-top system for real time gas and vapour analysis
Measures the concentration of gases and vapours in real time
The Hiden QGA quantitative gas analysis system is configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form. Inlet accessories are available to configure the system for sampling from low to high pressures, up to 30bar.
The Hiden QIC (quartz inert capillary) sampling interface samples from 100mbar to 2 bar gauge and is included as standard. Operating to 200oC, the QIC flexible 2m capillary inlet provides fast response times of less than 300 millisecond for most common gases and vapours, including water and organic vapours. Optimum sample integrity is maintained with sample exposure restricted to just quartz and platinum wetted surfaces.
The QGA system connects to an external dry scroll pump that is included to provide high performance combined sample bypass and UHV foreline pumping.
The QGA system has mass range 200 AMU (300 AMU option) and with a detection capability from 100% to less than 100 part-per-billion.
Overview
The Hiden QIC (quartz inert capillary) sampling interface samples from 100mbar to 2 bar gauge and is included as standard. Operating to 200oC, the QIC flexible 2m capillary inlet provides fast response times of less than 300 millisecond for most common gases and vapours, including water and organic vapours. Optimum sample integrity is maintained with sample exposure restricted to just quartz and platinum wetted surfaces.
The QGA system connects to an external dry scroll pump that is included to provide high performance combined sample bypass and UHV foreline pumping.
The QGA system has mass range 200 AMU (300 AMU option) and with a detection capability from 100% to less than 100 part-per-billion.
Features
- Simplified set up and operation from template files
- Real-time graphical and tabular data displays
- Automatic calibration with background correction
- Quantitative data output and data export for up to 16 species
- OPC data available as raw data or %/ppm quantitative output
- Gas/vapour mass spectral library with intelligent scan feature
- Precise fragmentation pattern recording
- Automatic subtraction of spectral overlaps
Specifications
Mass range |
200 or 300 amu |
Minimum detectable concentration |
100 PPB |
Maximum detectable concentration |
100% |
Sample inlet pressure |
100 mbar to 2 bar abs |
Sampling inlet |
Heated flexible silica capillary |
Standard capillary length |
2 meters |
Response time to gas concentration change |
300 milliseconds |
Fast measurement speed |
Up to 500 measurements per second |
Sample flow required (Standard) |
16 atm cc/min |
Sample flow required (Optional) |
< 1 atm cc/min to > 20 atm cc/min |
Corrosive gas sampling options |